mirror of
https://github.com/FirebirdSQL/firebird.git
synced 2025-01-22 19:23:02 +01:00
Use ERRORLEVEL consistently
This commit is contained in:
parent
23af5f9166
commit
034f8c0517
@ -16,6 +16,8 @@
|
||||
::
|
||||
::=============================================================================
|
||||
@echo off
|
||||
set SCRIPT_FULL_NAME=%~d0%~p0%~n0%~x0
|
||||
set SCRIPT_SHORT_NAME=%~n0%~x0
|
||||
|
||||
@goto :MAIN
|
||||
@goto :EOF
|
||||
@ -26,7 +28,7 @@
|
||||
|
||||
@echo off
|
||||
:: reset ERRLEV to clear error from last run in same cmd shell
|
||||
set ERRLEV=0
|
||||
set ERRLEV=
|
||||
|
||||
:: Assume we are preparing a production build
|
||||
set FBBUILD_BUILDTYPE=release
|
||||
@ -75,7 +77,7 @@ if "%FB2_SNAPSHOT%"=="1" (
|
||||
@for /f "usebackq tokens=*" %%c in (`where /f touch 2^>nul`) do set TOUCH_COMMAND=%%c
|
||||
if defined TOUCH_COMMAND (
|
||||
@%TOUCH_COMMAND% --version <nul >nul 2>nul
|
||||
if not errorlevel 1 (
|
||||
if not ERRORLEVEL 1 (
|
||||
@echo o POSIX touch utility found at %TOUCH_COMMAND%
|
||||
) else ( @set TOUCH_COMMAND= )
|
||||
)
|
||||
@ -229,13 +231,13 @@ set SED_COMMAND=sed -e s/\$MAJOR/%FB_MAJOR_VER%/g ^
|
||||
for %%f in ( msvcp%MSVC_RUNTIME_FILE_VERSION%.dll vcruntime%MSVC_RUNTIME_FILE_VERSION%.dll ) do (
|
||||
echo Copying "%VCToolsRedistDir%\%VSCMD_ARG_TGT_ARCH%\Microsoft.VC%MSVC_RUNTIME_LIBRARY_VERSION%.CRT\%%f"
|
||||
copy "%VCToolsRedistDir%\%VSCMD_ARG_TGT_ARCH%\Microsoft.VC%MSVC_RUNTIME_LIBRARY_VERSION%.CRT\%%f" %FB_OUTPUT_DIR%\ >nul
|
||||
if %ERRORLEVEL% GEQ 1 (
|
||||
call :ERROR Copying "%VCToolsRedistDir%\%VSCMD_ARG_TGT_ARCH%\Microsoft.VC%MSVC_RUNTIME_LIBRARY_VERSION%.CRT\%%f" failed with error %ERRORLEVEL% ) && (goto :EOF)
|
||||
if ERRORLEVEL 1 (
|
||||
call :ERROR Copying "%VCToolsRedistDir%\%VSCMD_ARG_TGT_ARCH%\Microsoft.VC%MSVC_RUNTIME_LIBRARY_VERSION%.CRT\%%f" failed with error %ERRLEV% ) & (goto :EOF)
|
||||
)
|
||||
)
|
||||
|
||||
@where /Q implib.exe
|
||||
@if not errorlevel 1 (
|
||||
@if not ERRORLEVEL 1 (
|
||||
if "%VSCMD_ARG_TGT_ARCH%"=="x86" (
|
||||
@echo Generating fbclient_bor.lib
|
||||
@implib %FB_OUTPUT_DIR%\lib\fbclient_bor.lib %FB_OUTPUT_DIR%\fbclient.dll > nul
|
||||
@ -262,8 +264,8 @@ if "%VSCMD_ARG_TGT_ARCH%"=="x86" (
|
||||
@mkdir %FB_OUTPUT_DIR%\doc
|
||||
@copy %FB_ROOT_PATH%\*.md %FB_OUTPUT_DIR%\doc\ > nul
|
||||
@copy %FB_ROOT_PATH%\doc\*.* %FB_OUTPUT_DIR%\doc\ > nul
|
||||
@if %ERRORLEVEL% GEQ 1 (
|
||||
call :ERROR COPY of main documentation tree failed with error %ERRORLEVEL%
|
||||
@if ERRORLEVEL 1 (
|
||||
call :ERROR COPY of main documentation tree failed.
|
||||
goto :EOF
|
||||
)
|
||||
|
||||
@ -272,16 +274,16 @@ if "%VSCMD_ARG_TGT_ARCH%"=="x86" (
|
||||
for %%d in ( v3.0 v4.0 ) do (
|
||||
mkdir %FB_OUTPUT_DIR%\misc\upgrade\%%d 2>nul
|
||||
@copy %FB_ROOT_PATH%\src\misc\upgrade\%%d\*.* %FB_OUTPUT_DIR%\misc\upgrade\%%d > nul
|
||||
@if %ERRORLEVEL% GEQ 1 (
|
||||
call :ERROR copy %FB_ROOT_PATH%\src\misc\upgrade\%%d\*.* %FB_OUTPUT_DIR%\misc\upgrade\%%d failed with error %ERRORLEVEL%.
|
||||
@if ERRORLEVEL 1 (
|
||||
call :ERROR copy %FB_ROOT_PATH%\src\misc\upgrade\%%d\*.* %FB_OUTPUT_DIR%\misc\upgrade\%%d failed.
|
||||
goto :EOF
|
||||
)
|
||||
)
|
||||
|
||||
:: INTL script
|
||||
@copy %FB_ROOT_PATH%\src\misc\intl.sql %FB_OUTPUT_DIR%\misc\ > nul
|
||||
@if %ERRORLEVEL% GEQ 1 (
|
||||
call :ERROR copy %FB_ROOT_PATH%\src\misc\intl.sql %FB_OUTPUT_DIR%\misc failed with error %ERRORLEVEL%.
|
||||
@if ERRORLEVEL 1 (
|
||||
call :ERROR copy %FB_ROOT_PATH%\src\misc\intl.sql %FB_OUTPUT_DIR%\misc failed.
|
||||
goto :EOF
|
||||
)
|
||||
|
||||
@ -298,38 +300,36 @@ for %%d in ( v3.0 v4.0 ) do (
|
||||
::)
|
||||
|
||||
@mkdir %FB_OUTPUT_DIR%\doc\sql.extensions 2>nul
|
||||
@if %ERRORLEVEL% GEQ 2 ( (call :ERROR MKDIR for doc\sql.extensions dir failed) & (@goto :EOF))
|
||||
@if ERRORLEVEL 2 ( ( call :ERROR MKDIR for doc\sql.extensions dir failed) & ( goto :EOF ) )
|
||||
@copy %FB_ROOT_PATH%\doc\sql.extensions\*.* %FB_OUTPUT_DIR%\doc\sql.extensions\ > nul
|
||||
@if %ERRORLEVEL% GEQ 1 ( (call :ERROR Copying doc\sql.extensions failed ) & (goto :EOF))
|
||||
@if ERRORLEVEL 1 ( ( call :ERROR Copying doc\sql.extensions failed ) & ( goto :EOF ) )
|
||||
|
||||
:: External docs aren't necessary for a snapshot build, so we don't throw
|
||||
:: an error if FB_EXTERNAL_DOCS is not defined. On the other hand,
|
||||
:: if the docs are available then we can include them.
|
||||
if defined FB_EXTERNAL_DOCS (
|
||||
@echo Copying pdf docs...
|
||||
@for %%v in ( Firebird_v%FB_MAJOR_VER%.%FB_MINOR_VER%.%FB_REV_NO%.ReleaseNotes.pdf ) do (
|
||||
@echo ... %%v
|
||||
@copy /Y %FB_EXTERNAL_DOCS%\%%v %FB_OUTPUT_DIR%\doc\%%v > nul
|
||||
if %ERRORLEVEL% GEQ 1 (call :ERROR Copying %FB_EXTERNAL_DOCS%\%%v failed.)
|
||||
:: if the docs are available then we must include them.
|
||||
@if defined FB_EXTERNAL_DOCS (
|
||||
echo Copying pdf docs...
|
||||
for %%v in ( Firebird-%FB_MAJOR_VER%.%FB_MINOR_VER%.%FB_REV_NO%%FBBUILD_FILENAME_SUFFIX%-ReleaseNotes.pdf ) do (
|
||||
echo ... %FB_EXTERNAL_DOCS%\%%v to %FB_OUTPUT_DIR%\doc\%%v
|
||||
copy /Y %FB_EXTERNAL_DOCS%\%%v %FB_OUTPUT_DIR%\doc\%%v > nul
|
||||
if ERRORLEVEL 1 ( call :ERROR Copying %FB_EXTERNAL_DOCS%\%%v to %FB_OUTPUT_DIR%\doc\%%v FAILED. & (@goto :EOF) )
|
||||
)
|
||||
|
||||
@for %%v in ( Firebird-%FB_MAJOR_VER%.%FB_MINOR_VER%-QuickStart.pdf ) do (
|
||||
@echo ... %%v
|
||||
@copy /Y %FB_EXTERNAL_DOCS%\%%v %FB_OUTPUT_DIR%\doc\%%v > nul
|
||||
if %ERRORLEVEL% GEQ 1 (
|
||||
for %%v in ( Firebird-%FB_MAJOR_VER%.%FB_MINOR_VER%-QuickStart.pdf ) do (
|
||||
echo ... %%v
|
||||
copy /Y %FB_EXTERNAL_DOCS%\%%v %FB_OUTPUT_DIR%\doc\%%v > nul
|
||||
if ERRORLEVEL 1 (
|
||||
REM - As of RC1 there is no quick start guide so we do not want
|
||||
REM the packaging to fail for something that doesn't exist
|
||||
if "%FBBUILD_FILENAME_SUFFIX%" == "-RC1" (
|
||||
echo Copying %FB_EXTERNAL_DOCS%\%%v failed.
|
||||
) else (
|
||||
call :ERROR Copying %FB_EXTERNAL_DOCS%\%%v failed.
|
||||
call :WARNING Copying %FB_EXTERNAL_DOCS%\%%v failed.
|
||||
)
|
||||
)
|
||||
)
|
||||
|
||||
|
||||
@echo Finished copying pdf docs...
|
||||
@echo.
|
||||
echo Finished copying pdf docs...
|
||||
echo.
|
||||
)
|
||||
|
||||
@echo Cleaning irrelevant files...
|
||||
@ -384,11 +384,11 @@ if %FB2_SNAPSHOT% EQU 1 (
|
||||
@if %MSVC_VERSION% EQU 15 (
|
||||
if not exist %FB_OUTPUT_DIR%\system32\vccrt%MSVC_RUNTIME_LIBRARY_VERSION%_%FB_TARGET_PLATFORM%.msi (
|
||||
"%WIX%\bin\candle.exe" -v -sw1091 %FB_ROOT_PATH%\builds\win32\msvc%MSVC_VERSION%\VCCRT_%FB_TARGET_PLATFORM%.wxs -out %FB_GEN_DIR%\vccrt_%FB_TARGET_PLATFORM%.wixobj
|
||||
@if %ERRORLEVEL% GEQ 1 (
|
||||
@if ERRORLEVEL 1 (
|
||||
( call :ERROR Could not generate wixobj for MSVC Runtime MSI ) & (goto :EOF)
|
||||
) else (
|
||||
"%WIX%\bin\light.exe" -sw1076 %FB_GEN_DIR%\vccrt_%FB_TARGET_PLATFORM%.wixobj -out %FB_OUTPUT_DIR%\system32\vccrt%MSVC_RUNTIME_LIBRARY_VERSION%_%FB_TARGET_PLATFORM%.msi
|
||||
@if %ERRORLEVEL% GEQ 1 ( (call :ERROR Could not generate MSVCC Runtime MSI %MSVC_RUNTIME_LIBRARY_VERSION% ) & (goto :EOF))
|
||||
@if ERRORLEVEL 1 ( ( call :ERROR Could not generate MSVCC Runtime MSI %MSVC_RUNTIME_LIBRARY_VERSION% ) & ( goto :EOF ) )
|
||||
)
|
||||
) else (
|
||||
@echo Using an existing build of %FB_OUTPUT_DIR%\system32\vccrt%MSVC_RUNTIME_LIBRARY_VERSION%_%FB_TARGET_PLATFORM%.msi
|
||||
@ -414,7 +414,7 @@ setlocal
|
||||
set OUTPATH=%FB_OUTPUT_DIR%\include
|
||||
@copy %FB_ROOT_PATH%\src\yvalve\perf.h %OUTPATH%\ > nul
|
||||
@copy %FB_ROOT_PATH%\src\include\gen\firebird.pas %OUTPATH%\firebird\ > nul || (@call :ERROR Failure executing copy %FB_ROOT_PATH%\src\include\gen\firebird.pas %OUTPATH%\firebird\ )
|
||||
@if %ERRLEV% GEQ 1 goto :END
|
||||
@if ERRORLEVEL 1 goto :END
|
||||
|
||||
endlocal
|
||||
|
||||
@ -440,8 +440,8 @@ copy %FB_ROOT_PATH%\builds\install\misc\databases.conf %FB_OUTPUT_DIR%\databases
|
||||
:: in builds\win32 by build_msg.bat. Copying from there to output dir
|
||||
::=================================================================
|
||||
@if not exist %FB_OUTPUT_DIR%\firebird.msg (
|
||||
(@copy %FB_GEN_DIR%\firebird.msg %FB_OUTPUT_DIR%\firebird.msg > nul)
|
||||
(@if %ERRORLEVEL% GEQ 1 ( (call :ERROR Could not copy firebird.msg ) & (goto :EOF)))
|
||||
(copy %FB_GEN_DIR%\firebird.msg %FB_OUTPUT_DIR%\firebird.msg > nul)
|
||||
(if ERRORLEVEL 1 ( ( call :ERROR Could not copy firebird.msg ) & ( goto :EOF ) ) )
|
||||
)
|
||||
|
||||
::End of FB_MSG
|
||||
@ -554,9 +554,11 @@ pushd %FBBUILD_INSTALL_IMAGES%
|
||||
call %MD5_COMMAND% Firebird-%PRODUCT_VER_STRING%?%FBBUILD_PACKAGE_NUMBER%*.* >md5sum.tmp
|
||||
|
||||
:: then rename it to the proper name
|
||||
if not errorlevel 1 (
|
||||
if not ERRORLEVEL 1 (
|
||||
del Firebird-%PRODUCT_VER_STRING%-%FBBUILD_PACKAGE_NUMBER%.md5sum >nul 2>nul
|
||||
ren md5sum.tmp Firebird-%PRODUCT_VER_STRING%-%FBBUILD_PACKAGE_NUMBER%.md5sum
|
||||
) else (
|
||||
(@echo Error calling %0 & popd & @goto :END)
|
||||
)
|
||||
popd
|
||||
|
||||
@ -621,20 +623,19 @@ popd
|
||||
|
||||
:ERROR
|
||||
::====
|
||||
:: errorlevel gets reset automatically so capture it before we lose it.
|
||||
set ERRLEV=%errorlevel%
|
||||
set ERRLEV=%ERRORLEVEL%
|
||||
@echo.
|
||||
@echo Error %ERRLEV% in BuildExecutableInstall
|
||||
@echo Error code %ERRLEV% in %SCRIPT_SHORT_NAME%
|
||||
@echo %*
|
||||
@echo.
|
||||
::End of ERROR
|
||||
::------------
|
||||
@goto :EOF
|
||||
@goto :END
|
||||
|
||||
|
||||
:WARNING
|
||||
::======
|
||||
set ERRLEV=%errorlevel%
|
||||
set ERRLEV=%ERRORLEVEL%
|
||||
@echo.
|
||||
@echo **** WARNING - Execution of a non-critical component failed with error level %ERRLEV%. ****
|
||||
@echo %*
|
||||
@ -645,8 +646,11 @@ if "%FBBUILD_PROD_STATUS%"=="PROD" (
|
||||
@echo Error %ERRLEV% must be fixed before continuing
|
||||
@echo.
|
||||
) else (
|
||||
set ERRLEV=0
|
||||
set ERRLEV=
|
||||
@ver > nul
|
||||
)
|
||||
::End of WARNING
|
||||
::--------------
|
||||
@goto :EOF
|
||||
|
||||
|
||||
@ -662,15 +666,15 @@ for %%v in ( %1 %2 %3 %4 %5 %6 %7 %8 %9 ) do (
|
||||
pushd ..\..\..\win32
|
||||
::This must be called from the directory it resides in.
|
||||
@call setenvvar.bat %*
|
||||
@if ERRORLEVEL 1 (popd & (call :ERROR Failure after calling setenvvar.bat ) & goto :END )
|
||||
popd
|
||||
@if errorlevel 1 (goto :END)
|
||||
|
||||
@if not defined FB2_ISS_DEBUG (set FB2_ISS_DEBUG=0)
|
||||
|
||||
@echo.
|
||||
@echo Reading command-line parameters...
|
||||
@(@call :SET_PARAMS %* )
|
||||
@if "%ERRLEV%"=="1" (@goto :ERROR %errorlevel% calling SET_PARAMS && @goto :END)
|
||||
@if ERRORLEVEL 1 (@call :ERROR Calling SET_PARAMS & goto :END)
|
||||
|
||||
@echo.
|
||||
@echo Checking that all required components are available...
|
||||
@ -730,11 +734,14 @@ if %FBBUILD_ISX_PACK% EQU 1 (
|
||||
|
||||
@(@call :DO_MD5SUMS ) || (@echo Error calling DO_MD5SUMS && @goto :END)
|
||||
|
||||
|
||||
@echo.
|
||||
@echo Completed building installation kit(s)
|
||||
@echo.
|
||||
|
||||
:: If we got this far then be sure to reset ERRLEV
|
||||
:: because run_all.bat will check for ERRLEV
|
||||
@set ERRLEV=
|
||||
|
||||
::@if %FB2_ISS_DEBUG% equ 0 (ENDLOCAL)
|
||||
::End of MAIN
|
||||
::-----------
|
||||
|
Loading…
Reference in New Issue
Block a user